Silicon TankTrace calculator

Estimate the DC drop in a copper trace

Take a trace 100 mm long, 1 mm wide, and 35 µm thick. At 20 °C, its cross section is 0.035 mm² and the estimated resistance is about 49.3 mΩ.

Convert resistance into voltage drop and loss

At two amps, current multiplied by resistance gives a drop of about 98.5 mV. Current squared multiplied by resistance gives about 197 mW of power loss. Two identical traces in series double both values.

Compare a voltage-drop target

For a 50 mV target at the same current, length, temperature and thickness, the single trace would need to be about 1.97 mm wide. The calculation uses the stated temperature, so a thermal estimate needs separate evidence about how the board sheds heat.

Use copper thickness after fabrication

Use the finished thickness stated by your board house for the specific layer. At 70 µm instead of 35 µm, the cross section doubles and the same single trace drops about 49.3 mV at two amps. Pads, vias and neck-downs can add resistance. Estimate sections separately and add their voltage drops along the current path.